Introduction
When used and controlled properly, geothermal heat pumps can save hundreds of dollars in heating and cooling
costs per year. Northern Heat Pump NorthStar Series geothermal heat pumps are designed to provide maximum
efficiency, comfort, and reliability. Solid and simple electric controls allow for low maintenance and built in
safety protection.
This is a prewired package system with the necessary controls for various forced air heating applications. The
EZGEO controller has a 4-position mode switch which allows various combinations of dual heat, AUX EL strip
heat, load control, etc. See the attached HC112 helps – EZGEO Controller.
The EZGEO controller is loaded with options and features you won’t find on other ground source heat pump
controls. The utility load control in the EZGEO system properly manages the cold weather heating mode and
properly controls the air conditioning mode during summer load interrupt. The blower control is designed to
allow the blower motor to operate continuously during cooling peak load interrupts.
Moving and Storage
Units should be stored in original packaging in a clean dry area. Store and move units in normal upright
position. Do not stack units.
Initial Inspection
Be certain to inspect all cartons and crates as units are received before signing the freight bill. Verify that all
items received have no physical damage. Report any damages or shortages on the freight bill. The purchaser is
responsible for filing the necessary claims with the carrier. Concealed or hidden damages not discovered until
removing packaging must be reported to the carrier within 15 days of receipt.
Unit Location and Mounting
Locate the unit in an indoor area where the ambient temperature will remain above 45°F [8°C]. Northern Heat
Pump provides 3 removable panels for ease of servicing; front (2), right and left bottom. This unit is zero
clearance rated; however, allow enough room to remove panels for service and maintenance. We suggest setting
the unit on a sound vibration pad, see accessories price sheet, R-PAD-2735-1-**. Water supply should not be
hard plumbed directly with copper pipe as this could transfer any vibration to living space.
Please read and understand conditions associated with proper installation, unauthorized changes, and POWER ON
procedures.
Warranty Statement
See the last page of this manual for detailed limited warranty coverage explanation.
Safety Considerations
WARNING
BEFORE PERFORMING SERVICE OR MAINTENANCE OPERATIONS ON A SYSTEM, TURN OFF
MAIN POWER SWITCHES TO THE INDOOR UNIT. IF APPLICABLE, TURN OFF THE ACCESSORY
HEATER POWER SWITCH. ELECTRICAL SHOCK COULD CAUSE PERSONAL INJURY.
Installing and servicing heating and air conditioning equipment can be hazardous due to system pressure and
electrical components. Only trained and qualified service personnel should install, repair or service heating and
air conditioning equipment. Untrained personnel can perform the basic maintenance functions of cleaning coils
and cleaning and replacing filters. All other operations should be performed by trained service personnel. When
working on heating and air conditioning equipment, observe precautions in the literature, tags and labels
attached to the unit and other safety precautions that may apply, such as the following safety measures:
Follow all safety codes.
Wear safety glasses and work gloves.
Use a quenching cloth for brazing operations.
Have a fire extinguisher available for all brazing operations.