09/11/2014 29 NI401
Undersized geothermal heat pump with fossil fuel furnace.
• Mode Dial: C
• SW Over Dial: 1=-15°F/ 2=-10°F/ 3=0°F/ 4=5°F/ 5=10°F/ 6=20°F/ 7=30°F
• AUX EL: 0
• SOT Dial: 0=30min 1=90min 2=180min 3=270min
• Thermostat type: Conventional 1H/2C
Geothermal heat pump with fossil fuel furnace.
• Mode Dial: C
• SW Over Dial: 0
• AUX EL: 0
• SOT Dial: 0=30min 1=90min 2=180min 3=270min
• Thermostat type: Conventional 1H/2C
Operation Indicators
Front Panel LED’s
- Hi-limit when the AUX EL hi-limit probe (automatic reset or manual reset)
opens this top red LED is on. The electric elements will be
interrupted via a safety relay circuit whenever this HL LED is
illuminated (mode B only).
- PWR ON indicates good fuse and 24-volt power source from the furnace
terminal block.
- See below for bad sensor indication.
- Status mode in some ways this can be a utility load control indicator, but
there are additional programmable functions which cause this unit
to go to standby (see HC112 EZGEO section and sequence charts).
- In addition this LED provides monitor for the two alarm conditions.
Dead compressor – fast pulsing, 1/10 second
ICM fault – slow pulsing, 1 second
- HP-Y1 – the output “Y” screw terminal is active at 24 volts high. This
provides the “Y” input to the ICM compressor monitor board.
Compressor will react as a function of this ICM safety board.
- HP-Y2 – not used on single stage models.
- T-stat call – the room thermostat W or Y is active or 24 volts high.
- Gas call the furnace “W” or terminal block feeding furnace W, 24 volts
high.