11 Appendix
V
Z
N
V2
N2
V3
N3
V4
N4 N4
V1
N1
C
C13 C15C11 C12
C14
C16
C25
C23
C24
C22
C32
C34
C36
C35
C31
C33
C21
A
A1
A2
A3
A4
A5 A6
B
B1
B2
B3
B4
B5
F
F1
F2
F3
F4
F5
F6
O
O1
O2
O3 (3)
O3 (2)
O3 (1)
O311
O312
O313
O321
O331
O332
O333
Z1 Z2 Z3
Z4
Z5
Z6
Z
Current offset is
displayed
, -2.00...2.00 pH
, -120...120 mV
, -50.0...50.0 %
0.00 pH
0mV
0.0 %
Function group
OFFSET
Function group
NUMERIC
CALIBRATION
Calibration status
is displayed
o.k.
E--
Offset results
; no; newyes
Entry of absolute value
-2.00...16 pH
-1500...1500 mV
0.0...100.0 %
current measured value
Enter slope
38.0065.00 mV/pH
Antimon 59.16 mV/ pH
25.00 65.00 pH
IsFET
Glass 59.18 mV/pH
Enter zero point
5.009.00 pH
Antimon 1.00 pH
1.00 3.00 pH
IsFET
Glass 7.00 pH
Calibration status
is displayed
E---
o.k.
Store calibration
results
; no; newyes
Enter reference
temperature
25 °C
-20.0...150.0 °C
Function group
CALIBRATION
Redox %
calibration
Redox mV
calibration
pH
calibration
(calibration type options
displayed depend on
selection in field A1)
Calibration
Acceptance when stable
0,05 pH for more
than 10 s
≤±
Calibration
Acceptance when stable:
0,05 pH for more
than 10 s
≤±
Enter calibration
temperature
(if B3 = MTC)
-20.0...150.0 C
25.0 C°
°
Entry of pH value of
first buffer solution
0.00 pH...14.00 pH
Buffer value from last
calibration
Entry of pH value of
second buffer solution
0.00 pH...14.00 pH
Buffer value from last
calibration
Store calibration
results
; no; newyes
Zero point is displayed
-100...100 mV
Calibration status
is displayed
o.k.
E--
Calibration
Acceptance when stable
1 mV for more than 5 s≤±
Calibration
Acceptance when stable
5 mV for more than 5 s≤±
Calibration
Acceptance when stable
5 mV for more than 5 s≤±
Calibration status
is displayed
o.k.
E--
Calibration of 80%
value (toxic sample)
-1500...1500 mV
Calibration of 20%
value (non-toxic
sample)
-1500...1500 mV
Enter value of
redox buffer
-1500 mV ... 1500 mV
current measured value
Display of slope
Glass
38.00...65.00 mV/pH
Antimon
25.00...65.00 mV/pH
38.00 65.00 mV/pH
59.16 mV/pH
59.16 mV/pH
IsFET 59.16 mV/pH
Store calibration
results
; no; newyes
MEAS. VALUE DISPLAY
with
TEMPERATURE DISPLAY
in °C
Measured value display
in mV
Temperature display
suppressed
Temperature display
in °F
Other errors
are displayed
(up to 10 errors)
1st error is displayed
(if present)
Edit mode:
code 22
Read mode:
any code
Edit mode:
code 22
Read mode:
any code
Measured value display
Current input in %
Measured value display
Current input in mA
Function group
SETUP 1
Selection of
operation mode
; ORP (mV);
ORP (%)
pH
Selection of connection
type
asym = asymmetrical
sym = symmetrical
Selection of display unit
ORP
pH
Entry of measured
value damping
(no damping)
1-60
1
Selection of electrode
Glass (E = 7,0)
Antim = Antimon
0
IsFET
Selection of
temperature sensor
Pt 100
NTC 30K
Pt 1k
Function group
SETUP 2
Temperature compensation
selection (for process)
pH: Redox:
on
MTC
ATC;
off
Entry of MTC
temperature
(if B1=MTC
and A1=pH)
-50...+150
25.0 °C
°C
Temperature compensation
selection
(for calibration)
; MTCATC
Entry of correct
process temperature
(if B1=ATC)
25.0°C
-50.0°C ... +150.0°C
Display of
temperature difference
(offset)
0.0°C
-5.0...5.0 °C
Cont. switch-off
by current input
InputOff;
Switch-off direction
for current input
HighLow;
Feedforward control
to PID controller
lin = linearOff;
Delay for cont.
switch-off current input
0 ...2000 s0s
Delay for cont.
switch-on current input
0 ...2000 s0s
Switch-off limit value
for current input
0 ... 100%50%
Function group
CURRENT INPUT
Function group
CURRENT OUTPUT
Current output selection
; Out2;Out1
Current output selection
; Out2;Out1
Characteristic selection
Tab = table
sim = simulation
lin = linear
Current range selection
0-20 mA4-20 mA;
0/4 mA value entry
+ -2.00...16.00 pH
-1500...1500 mV
0.0...100.0 %
2.00 pH;
-1500 mV;
0.0 %;
0.0°C; -50...150.0°C
20 mA value entry
-2.00...16.00 pH
-1500...1500 mV
0.0...100 %
12.00 pH;
1500 mV;
100.0 %;
100.0°C; -50...150.0°C
Entry of simulation value
0... 22.00 mA
current value
Table options selection
edit
read;
Set number of
value pairs in table
1...10
1
Seleciton of
table value pair
1...Number of
table value pairs;
asign
1
Function group
ALARM
Select contact type
= steady contact;
Fleet = fleeting contact
Stead
Select alarm
delay unit
;mins
Alarm delay
0 s... 2000 s (min)
(depends on F2)
0s(min)
Error current
setting
2,4 mA
22 mA;
Error number
selection
1... 255
1
Set alarm contact
to be effective
;noyes
Appendix Liquisys M CPM 223 / 253
82 Endress+Hauser